STANDARD OPERATING PROCEDURE

STANDARD OPERATING PROCEDURE

Add a ptfe magnetic stir bar. Close with a white sleeve-type serum stopper. Secure the serum stopper sleeve using a hose-clamp. Add dry ice to the Dewar and cool the 2-propanol with stirring. 1.3 Subject the cold 2-propanol to three evacuation-nitrogen equilibration purges on the Schlenk line. Follow the SSRL SOP for degassing water.

More details
SOP: Permanganate Oxidizable Carbon (POXC)

SOP: Permanganate Oxidizable Carbon (POXC)

Add a stir bar to the beaker, place on a magnetic stir plate and stir until completely dissolved. 2. Transfer to a 1000 mL volumetric flask or graduated cylinder. Bring to volume with deionized water. 3. Weigh 31.60 g of KMnO. 4. into a 1000 mL beaker and add approximately 900 mL of the CaCl. 2. solution. Place on the magnetic stir plate with ...

More details
INSTRUKSI KERJA ALAT LABORATORIUM PENELITIAN

INSTRUKSI KERJA ALAT LABORATORIUM PENELITIAN

Cara Kerja Magnetic Stirrer With Hot Plate : 1. Pasang kabel power ke sumber listrik. 2. Atur suhu yang diinginkan dengan memutar Tombol Heat. 3. Lampu indicator menyala menandakan unit sedang bekerja. 4. Setiap nilai yang ditetapkan akan dipertahankan apabila perangkat dimatikan atau terputus dari hubungan listrik.

More details
SOP for Magnetic Stirrer with Hot Plate

SOP for Magnetic Stirrer with Hot Plate

Dec 28, 2022 To describe the procedure for operation of the Magnetic stirrer with the hot plate. 2.0 SCOPE This SOP is applicable for operation Magnetic stirrer with the hot plate. 3.0 RESPONSIBILITY Officer/ Executive - Quality Control 4.0 ACCOUNTABILITY Manager - Quality Control 5.0 PROCEDURE 5.1 Operation

More details
Instruction Manual Hotplates Stirrers Hotplate-Stirrers

Instruction Manual Hotplates Stirrers Hotplate-Stirrers

Hotplate Stirrer Hotplate-Stirrer 120V: 7.9 amps/950 watts 0.4 amps/50 watts 8.3 amps/1000 watts 230V: 4.4 amps/1000 watts 0.2 amps/50 watts 4.6 amps/1050 watts Fuses: HP / HPS 5mm x 20mm, 10 amp slow blow Stirrer 5mm x 20mm, 5 quick acting Temperature range: ceramic: ambient +5C to 500C aluminum: ambient +5C to 400C

More details
Isotemp Hotplates Stirrers and Stirring Hotplates

Isotemp Hotplates Stirrers and Stirring Hotplates

Isotemp Hotplates, Stirrers and Stirring Hotplates OPERATION MANUAL AND PARTS LIST Catalog # Type Top Plate Size and Material Voltage 11100100H Hotplate 10x10 Ceramic 120 11100100S Stirrer 10x10 Ceramic 120 11100100SH Stirring Hotplate 10x10 Ceramic 120 1110016H Hotplate 4x4 Ceramic 120 1110016S Stirrer 4x4 Ceramic 120

More details
cGMP and Regulatory Updates: SOP - OPERATION PROCEDURE FOR MAGNETIC STIRRER

cGMP and Regulatory Updates: SOP - OPERATION PROCEDURE FOR MAGNETIC STIRRER

Jul 27, 2008 1.0 OBJECTIVE To ensure that Magnetic Stirrer with hot plate performs satisfactorily. 2.0 SCOPE This sop covers the operation procedure for Magnetic stirrer with hot plate and this is applicable to Quality control department..

More details
Mechanical Stirrer - SOP for Cleaning and Operation

Mechanical Stirrer - SOP for Cleaning and Operation

Jun 29, 2020 Cleaning Procedure of Mechanical Stirrer : Product to Product Cleaning Procedure: Ensure that ‘To be Cleaned’ label is affix on the equipment. Switch ‘OFF’ the mains of the Stirrer. Remove the stirrer shaft from stirrer and then clean with NLT 2 liters of potable water. Then scrub the stirrer shaft with half liters of 2% non-ionic ...

More details
Mechanical Stirrer - SOP for Cleaning and Operation - Pharma Beginners

Mechanical Stirrer - SOP for Cleaning and Operation - Pharma Beginners

Jun 29, 2020 Standard Operating Procedure (SOP) for cleaning and operation of Mechanical Stirrer used in granulation at drug product manufacturing in pharmaceuticals. SOP for Cleaning and Operation of Mechanical Stirrer 1.0 PURPOSE: The purpose of this SOP is to lay down the cleaning and operation procedure for Mechanical Stirrer. 2.0 SCOPE:

More details
Magnetic stirrer Calibration SOP - Pharmaceuticals Industry

Magnetic stirrer Calibration SOP - Pharmaceuticals Industry

Magnetic stirrer Calibration SOP. 1.0 OBJECTIVE: To lay down the calibration procedure of Magnetic stirrer to provide a system to calibrate, control and maintain the equipment used for inspection measuring and test equipment in order to ensure the correctness of measurement and test status. 2.0 SCOPE:

More details
Magnetic Stirrer MOBIL DIRECT Operating Manual

Magnetic Stirrer MOBIL DIRECT Operating Manual

Magnetic stirrer: 10 to +56 C at max. 100 % RH Power supply: +5 to +40 C at max. 80 % RH See Technical Specifications. The magnetic stirrer must not be operated in a water bath. The power supply unit must not be run in humid rooms, or set up in wa-ter splash zones. CAUTION! The magnetic stirrer must be switched off before connecting or pulling

More details
Standard Operating Procedures

Standard Operating Procedures

Page 3 PETC of 3 Emulsiflex Standard Operating Procedure Protocol/Procedure ... The sample (well mixed, typically by stirring on a magnetic stir plate) is poured into the sample reservoir. 4) Start the instrument as before. 5) Once sample begins to exit the outlet increase the homogenizing pressure, monitored by the small gauge, by turning the ...

More details
Magnetic Stirrer Operating Manual - Cole-Parmer

Magnetic Stirrer Operating Manual - Cole-Parmer

Programs can be selected only if the stirrer has been turned off. When the stirrer is turned on, the last program selected will be active. Speed, stirring power, and stirring mode settings are stored as a part of the currently active program. 50%rpm750 * Figure 3: Stirring display : The stirring bar symbol turns when the stirrer is active.

More details
Heidolph Instruments : Operation Manuals

Heidolph Instruments : Operation Manuals

Rotary Evaporators Large-Scale Rotary Evaporators Automatic Module Hei-VOLUME Distimatic Magnetic Stirrers Overhead Stirrers Shakers Mixers Peristaltic Pumps Processing Solutions Smart cell cultivation

More details
Standard Operating Procedures - BB3R

Standard Operating Procedures - BB3R

Standard Operating Procedure (SOP) Title Viability assessment of cell monolayers with MTT reduction assay in 96-well plates Date 2017-01-05 Document No. SOP_MTT96 First edition 2014-07-03 ... Magnetic stirrer RCT basic IKA-Werke, Staufen Microtome (Hyrax M40) Zeiss, Jena

More details
Operation Manual Magnetic Stirrer RT Basic Layout 1

Operation Manual Magnetic Stirrer RT Basic Layout 1

The Magnetic Stirrer RT Basic is an economically compact and lightweight magnetic stirrer for any experimental lab environment. This stirrer has an operating range of 150rpm ~ 2,500rpm by exact speed and powerful performance provides stirring of high viscosity solutions. This magnetic stirrer is designed for user safety in the laboratory. A

More details
Magnetic Stirrers Brochure - Laboratorio.Shop

Magnetic Stirrers Brochure - Laboratorio.Shop

The wear-free magnetic coil technology provides consistent and noiseless stirring on all positions. The RT series of magnetic stirrers are available with 5, 10 and 15 stirring positions and can be used for volumes up to 6 l (H 2 O). The new RO series of multi-position digital magnetic stirrers without heating are ideal for synchronous stirring.

More details
SOP for Stirrer : Pharmaceutical Guidelines

SOP for Stirrer : Pharmaceutical Guidelines

To lay down the procedure for Operation of Stirrer. 2.0 SCOPE To lay down the procedure for Operation of Stirrer. 3.0 RESPONSIBILITY 3.1 Execution: Operator 3.2 Checking: Production Pharmacist Above 4.0 ACCOUNTABILITY HOD-Production / Assigned Designee 5.0 …

More details
(Hotplate) Magnetic Stirrer - Biosigma

(Hotplate) Magnetic Stirrer - Biosigma

Welcome to the “ (Hotplate) Magnetic Stirrer”. Users should read this Manual carefully, follow the instructions and procedures, and be aware of all the cautions when using this instrument. Service When help needed, you can always contact the Service Department of manufacturer for technical support in the following ways: